MAIN FEATURES
Smart remote control (RMT/RJ 11 or RJ45)
Battery temperature sensor (BTS)
Automatic generator starting (AGS)
Designed to operate under harsh environment
DC start & automatic self-diagnostic function
Compatible with both linear & non-linear load
Easy to install & easy to operate & easy to solve
Low DC voltage supports home & office appliances
Powerful charge rate up to 120Amp, selectable from 0%-100%
High efficiency design & “Power Saving Mode” to conserve energy
Battery priority mode, designates inverter-preferred UPS configuration
8 pre-set battery type selector plus de-sulphation for totally flat batteries
4-step intelligent battery charging, PFC (power factor correction) for charger
8ms typical transfer time between utility & battery, guarantees power continuity
15s delay before transfer when AC resumes, protection for load when used with generator
TECHNICAL SPECIFICATIONS
2KW X SERIES TECHNICAL SPECIFICATIONS
General
Model: Bersh X series.
Rated Power: 2000 W.
Input
Voltage: 180 – 300 VAC.
Frequency Range: 47 Hz/55 Hz (Auto sensing).
Output
AC Voltage Regulation (Batt. Mode): 220/230/240VAC ± 10%.
Surge Power: 6000VA.
Efficiency (Peak): 88%.
Transfer Time
Less than 10ms
Waveform
Pure sine wave.
TDH
Less than 3%(Rated battery level, rated full linear load)
Battery & AC Charger
Battery Voltage: 24VDC
Overcharge Protection: 33 VDC.
Maximum AC Charge Current: 35 A.
Battery Selector
Cooling
Force Air
Physical
Dimension, L x W X H (mm): 550 x 415 x 310.
Net Weight (kgs): 11.4.
Operating Environment
Humidity: 0 to 95% Relative Humidity(Non-condensing).
Operating Temperature: -10°C to 40°C.
Storage Temperature: -40°C to 70°C